Vertically and horizontally scalable
Conceptpower DPA 240 provides power protection from 40 to 1.2 MW at 415V (one to six modules) in a single cabinet, on both input and output. Horizontal scalability up to five cabinets in parallel is possible to increase the total power to 1.2 MW. This scalability means there is no need to oversize the original configuration as power modules can be easily added in the future when needed.
True parallel architecture
This advanced UPS design provides the highest level of protection in critical applications where the load must be supplied with quality power. Conceptpower DPA systems use decentralized parallel architecture and provide the highest level of reliability and availability with true redundancy between modules.
| GENERAL DATA |
Conceptpower DPA 240 UL UPS |
| System power range |
40 kW–1.2 MW |
| Nominal power/module |
40 kW |
| Nominal power/cabinet (capacity) |
320 kW |
| Output power factor |
1.0 |
| Topology |
Double conversion, transformerless, modular Distributed Parallel Architecture |
| Parallel configuration |
Up to 6 modules in one frame / up to 5 frames in parallel |
| Cable entry |
Bottom entry |
| Serviceability |
Front access only |
| Rear side protection |
B1-a (included) |
| Connection |
3-phase + Neutral + Ground |
| INPUT |
|
| Nominal input voltage |
3 × 480/277 V / neutral + ground |
| Voltage tolerance |
±10% (100% load), ±20% (80%), ±30% (60%), ±35% (40%) |
| Input harmonic distortion THDi |
<3% (at 100% load) |
| Frequency range |
50/60 Hz ±5% |
| Power factor |
0.99 @ 100% load |
| Backfeed current |
None |
| OUTPUT |
|
| Nominal output voltage |
3 × 480/277 V / neutral + ground |
| Voltage tolerance |
±1% |
| Voltage distortion THDv |
<2% in linear mode |
| Frequency |
50/60 Hz |
| WEIGHT & DIMENSIONS |
|
| Weight (System, with 6 modules) |
1276 lbs (580 kg) |
| Dimensions (W×D×H) |
31.1" × 37.8" × 51.7" (791 × 960 × 1315 mm) |
Module Includes:
- 40kW
- True Online Double Conversion UPS.
- High Modular Component.
- Internal Power Electronics.
- Integrated Module Indicator.
- Wide Screen HMI Interface with Microprocessor for External Information Display.
Frame Includes:
- Up to 320kVA Nominal Power.
- Bottom cable entry (Standard).
- Bypass, Input/Current Terminal (Load or UPS Input Mains/Bypass Available) and UPS Output Terminal.
- Static Bypass Relay and Main Breaker (Between Y Output).
- Monitoring and Alarm Relays.
- Integrated Overvoltage and Surge HMI Indicator.
Options
- Static Bypass Relay.
- External Bypass Control.
- Battery Circuit Breaker.
- Monitoring and Management (Optional with Modbus RS-485, Modbus TCP/IP, SNMP, Bacnet I/O).
- External Input/Output Module Support.